Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14510994 - EMPLOYEES BURNED IN CRUDE OIL FIRE

Accident Summary Nr: 14510994 -- Report ID: 0625400 -- Event Date: 03/20/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
1750421803/21/198613890Chuck'S Hot Oil Service

Abstract: AT APPROXIMATEKY 5 PM ON MARCH 20, 1986, EMPLOYEE #1 WAS USING A TRUCK MOUNTED HOT OIL UNIT TO PUMP HOT (260 DEGREES) CRUDE OIL, UNDER ABOUT 600 PSI PRESSURE, INTO THE CASING HEAD OF AN OIL AND GAS PRODUCING WELL. THE HOT OIL WAS BEING USED TO MELT PARAFFIN IN THE WELL. AS EMPLOYEE #1 WAS ENGAGED IN THIS OPERATION, ANOTHER EMPLOYEE (EMPLOYEE #2) ARRIVED WITH ANOTHER HOT OIL UNIT AND PARKED ADJACENT TO THE HOT OIL UNIT IN USE. SUDDENLY A DISCHARGE HOSE RUPTURED AND HOT OIL STARTED FLOWING BACK FROM THE WELL. THE HOT OIL WAS IGNITED BY FLAMES FROM THE FIRE BOX OF THE HEATER ON THE UNIT IN USE. EMPLOYEE #1 WAS BURNED OVER 97% OF HIS BODY. EMPLOYEE #2 RECEIVED ONLY MINOR BURNS ON HIS FINGERS WHICH HE SUFFERED WHEN HE WENT TO ASSIST EMPLOYEE #1. BOTH EMPLOYEES WERE TRANSPORTED TO THE HOSPITAL. EMPLOYEE #2 WAS RELEASED THE SAME DAY, BUT EMPLOYEE #1 DIED ON APRIL 17TH AS A RESULT OF THE SEVERE BURNS HE SUFFERED. CAUSAL FACTORS: THE HOT OIL UNIT HAD NO PRESSURE RELIEF DEVICE ON THE PISTON PUMP; THERE WAS NO CHECK VALVE IN THE OIL LINE TO PREVENT BACK FLOW FROM THE WELL; THE DISCHARGE LINE WAS NOT PRESSURE TESTED BEFORE USE.

Keywords: BURN, FIRE, OIL WELL DRILLING, HOSE, RUPTURE, CRUDE OIL, HIGH PRESSURE, HIGH TEMPERATURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 17504218 Fatality Burn/Scald(Heat) Occupation not reported
2 17504218 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close