Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14507297 - CRUSHED BY HEAD FRAME OF HYDRAULIC RAISE BORE MACHINE

Accident Summary Nr: 14507297 -- Report ID: 0830500 -- Event Date: 03/21/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
150966003/22/198535320Stu Blattner Inc

Abstract: EMPLOYEE #1 WAS WORKING UNDERNEATH A HYDRAULIC RAISE BORE MACHINE. AFTER THE FORKLIFT TRUCK RAISED THE HEAD FRAME, EMPLOYEE #1 PROPPED A RAILROAD TIE UNDER THE CENTER OF THE FRAME. WHILE EMPLOYEE #1 WAS UNDERNEATH THE FRAME DISCONNECTING THE RIGHT HYDRAULIC ERECTION CYLINDER, THE RAILROAD TIE SLIPPED OUT FROM UNDER THE FRAME. THE FRAME CAME DOWN AND CRUSHED EMPLOYEE #1.

Keywords: REPAIR, BLOCKS, CRUSHED, INDUSTRIAL TRUCK, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1509660 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close