Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14503858 - Employee killed in 200 ft fall from microwave tower

Accident Summary Nr: 14503858 -- Report ID: 0729700 -- Event Date: 08/12/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10310095408/16/198817990Utility Tower Co.

Abstract: Employees were removing 1,000 ft of 5 in. coaxial cable from a 1,154 ft tall radio tower. They were using a system of rigged lines and hoisting grips, which were spaced every 200 ft, to remove 200 ft of cable at a time. A safety backup line that used a barrel hitch had also been attached just below the hoisting grip to each of the three 200 ft sections that the workers had removed from the top. Employee #1 was at the 200 ft level on the tower. In preparation for sawing the cable, he had removed the cable brackets that held it to the tower. The weight of the cable, which had not yet been transferred over to the rigged lines by his coworker at the 400 ft level, was being held only by the hoisting grip. The cable came out of the hoisting grip and struck Employee #1. His safety belt link failed and he fell to the ground. Employee #1 was killed.

Keywords: COMMUNICATION TOWER, WIRE ROPE, INADEQUATE MAINT, SAFETY BELT, CONSTRUCTION, EQUIPMENT FAILURE, FALL, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103100954 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.