Accident Summary Nr: 14468128 - RADIO TOWER COLLAPSE

Accident Summary Nr: 14468128 -- Report ID: 0155010 -- Event Date: 04/05/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
328660604/05/198617990Prescott Towers Ltd.

Abstract: A 415' RADIO TOWER WAS BEING ERECTED IN A SWAMP. ONE OF THE THREE TIEDOWN ANCHORS, SPACED 120' APART AND 280' FROM THE TOWER BASE, FAILED WHILE EMPLOYEES #1 AND #2 WERE ON THE TOWER AND TIED OFF AT 220' AND 240' ELEVATIONS RESPECTIVELY. BOTH EMPLOYEES, AFTER RIDING THE TOWER DOWN, DIED ON IMPACT OF MULTIPLE BLUNT TRAUMA. TWO 100' HIGH-STRENGTH WIRE STRAND CABLES (.6"7-WIRE), PROTRUDING 6' FROM A MINI-CAISSON (5 1/2" CASING) DRILLED AT 38' FROM THE HORIZONTAL, WERE NOT IN CONTINUOUS LENGTHS. A PROTRUDING 6' TIEDOWN CABLE PULLED OUT OF A "SUPREME" ONE-TIME-USING (OUT) SPLICE CHUCK #S740 LOCATED JUST 6" INSDE OF CASING. BOTH CABLES WERE TESTED AT 125% OF THE DESIGN LOAD SIMULTANEOUSLY RATHER THAN INDEPENDENTLY. TOWER ERECTION AND ANCHOR INSTALLATION PERFORMED BY SEPARATE CONTRACTORS.

Keywords: ERECTION PROCESS, COLLAPSE, CONSTRUCTION, STEEL ERECTION, FALL, TOWER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3286606 Fatality Other Construction trades, n.e.c.
2 3286606 Fatality Other Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close