Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14465645 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 14465645 -- Report ID: 0626600 -- Event Date: 04/12/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11031577704/16/199017910Cbi Na-Con, Inc.

Abstract: A four-person crew was moving a pallet supporting a pump motor to a different location so that a sea container could be placed where the pallet had been. A 12.4-kilovolt overhead power line that was 11.6 meters above the ground was located over the pallet. One of the employees rigged the load to a Lorain 45-metric-ton crane and signaled the operator to move the load. The crane operator moved the boom. The tip of the boom, which had been extended 11.7 meters, contacted the power line. The employee who had signaled the crane operator was holding a chain sling when the boom contacted the power line. He was electrocuted. The crane operator saw the injured employee fall to the ground and thought he had been struck by the load. The operator moved the load immediately and turned the crane off. A helper, who had been holding the wooden pallet at the time of the accident, was not injured.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110315777 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.