Accident Summary Nr: 14465116 - PRECAST CONCRETE PANEL FELL ON EMPLOYEES.

Accident Summary Nr: 14465116 -- Report ID: 0551800 -- Event Date: 04/11/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1469485504/12/198417910Geiger & Peters Inc

Abstract: ON APRIL 11, 1984, AT 3:30 - 3:45 PM, EMPLOYEES #1,2, AND 3 WERE PLACING CRIBBING FOR SUPPORT OF AN OUTRIGGER ON A GROVE CRANE, SERIAL NUMBER 33674, MODEL RT 655, WHEN THEY WERE STRUCK BY A FALLING PRECAST CONCRETE PANEL WEIGHING 21,372 POUNDS. THE PANEL WAS BEING SET ON THE EAST WALL OF THE BUILDING , BUT HAD TEMPORARILY BEEN PLACED ON THE GROUND, AND SUPPORTED AGAINST THE BUILDING STEEL WHILE THE CRIBBING WAS BEING COMPLETED. EMPLOYEE #1 HAD BEEN PICKING UP CRIBBING MATERIAL AND WAS NEAR THE CENTER OF THE PANEL WHEN IT FELL ON HIM, CAUSING FATAL HEAD INJURIES. EMPLOYEE #2 WAS ON THE NORTH SIDE OF THE CRIBBING OPERATION AND WAS PUSHED 10 - 15 FEET TO THE NORTHEAST, SUFFERING ABRASIONS ON HIS RIGHT ARM. EMPLOYEE #3 WAS ON THE SOUTH SIDE OF THE CRIBBING OPERATION AND WAS PINNED UNDER THE PANEL. HE SUFFERED A BROKEN CLAVICLE AND A NECK LACERATION. THE PANEL HAD BEEN LEFT STANDING UPRIGHT , UNSECURED, ON SOFT SOIL WHILE THE EMPLOYEE'S ATTENTION WAS FOCUSED ON THE CRIBBING OPERATION. THE CRANE OUTRIGGER HAD NOT BEEN SUPPORTED PROPERLY FOR THE EXISTING SOIL CONDITIONS.

Keywords: FRACTURE, HEAD, CRANE OUTRIGGER, CONCRETE PANEL, CRUSHED, LACERATION, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14694855 Non Hospitalized injury Fracture Structural metal workers
2 14694855 Fatality Fracture Structural metal workers
3 14694855 Non Hospitalized injury Bruise/Contus/Abras Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close