Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14454656 - EMPLOYEES OVEREXPOSED TO CARBON MONOXIDE FROM FORKLIFT

Accident Summary Nr: 14454656 -- Report ID: 0751910 -- Event Date: 09/29/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10424095708/30/198920130Beef Specialists Of Iowa Inc.

Abstract: ON AUGUST 29, 1989 EMPLOYEE #9 OPERATED A FORKLIFT TO TRANSPORT BEEF IN AND OUT OF THE FREEZER. THE REGULAR FORKLIFT BROKE DOWN IN THE MORNING AND A HYSTER LP-POWERED FORKLIFT WAS USED FOR 2 HOURS WITH HIGH EMISSIONS OF CARBON MONOXIDE. THE FORKLIFT WAS OPERATED NEAR THE TRIMLINE WHERE EMPLOYEES #1 THROUGH #8 WORKED. ALL THE EMPLOYEES EXPERIENCED HEADACHES AND NAUSEA. THE OPERATION WAS SHUT DOWN AT 2 PM AND EMPLOYEES #1 THROUGH #9 WERE TAKEN TO THE EMERGENCY ROOM AND FOUND TO HAVE CARBON MONOXIDE HEMOGLOBIN LEVELS RANGING FROM 7.2 TO 24.6 PERCENT. THE HYSTER PROBLEM FORKLIFT WAS FOUND TO HAVE CARBON MONOXIDE EXHAUST EMISSIONS OF 6-8000 PPM. EMPLOYEE #9 HAD THE HIGHEST CARBON MONOXIDE HEMOGLOBIN READING AND EMPLOYEE #1 HAD THE LOWEST.

Keywords: RESPIRATORY, IND TRK OPERATOR, HEADACHE, NAUSEA, INDUSTRIAL TRUCK, AIR CONTAMINATION, EXHAUST FUMES, LP GAS, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
2 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
3 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
4 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
5 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
6 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
7 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
8 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
9 104240957 Non Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close