Accident Summary Nr: 14437735 - 2 EMPLOYEES KILLED, ONE INJURED WHEN PAINT FUMES EXPLODED

Accident Summary Nr: 14437735 -- Report ID: 1032500 -- Event Date: 05/16/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10702631205/17/198917210T.M.K. Company Dba Terry Crofts Painting Service

Abstract: ON MAY 16, 1989, EMPLOYEE #1 WAS SPRAY PAINTING A SEALED-OFF ROOM IN A HOUSE. THE WINDOWS AND DOORS WERE ALL CLOSED AND THE ROOM WAS SEPARATED FROM THE REST OF THE HOUSE BY A VISQUEEN SHEET. EMPLOYEES #2 AND #3 WERE WORKING IN AN ADJACENT ROOM. A SPARK (SOURCE UNKNOWN) IGNITED THE PAINT FUMES, WHICH HAD SPREAD THROUGHOUT THE EAST END OF THE HOUSE. EMPLOYEE #1 WAS SEVERELY BURNED AND DIED AT THE SCENE. THE TWO OTHER EMPLOYEES WERE SERIOUSLY BURNED AND TRANSPORTED TO A BURN CENTER. EMPLOYEE #2 DIED AT THE BURN CENTER. EMPLOYEE #3 SURVIVED AND IS BEING TREATMENT FOR THE BURNS HE SUSTAINED. THE COMPANY WAS ISSUED CITATIONS FOR THE LACK OF A HAZARD COMMUNICATION PROGRAM, FAILURE TO ELIMINATE IGNITION SOURCES, AND FAILURE TO PROVIDE ADEQUATE VENTILATION.

Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, FIRE, PAINT, EXPLOSION, PAINTER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107026312 Fatality Burn/Scald(Heat) Occupation not reported
2 107026312 Fatality Burn/Scald(Heat) Occupation not reported
3 107026312 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.