Accident Summary Nr: 14424428 - FIVE EMPLOYEES INHALED TOXIC FUMES FROM EXHAUST HOOD

Accident Summary Nr: 14424428 -- Report ID: 0729300 -- Event Date: 03/06/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10670229303/09/199236740Memc Electronics Materials

Abstract: DURING THE NORMAL ETCHING PROCESS OF SILICON WAFERS THE EXHAUST FAN USED TO VENTILATE AN ENCLOSED HOOD STOPPED WORKING. THE HOOD ENCLOSED AN AUTOMATED PROCESS WHERE SILICON DISCS ARE FIRST DIPPED INTO A SOLUTION OF KOH AT 45% AND ABOUT 90 DEGREES C, AND THEN TRANSFERRED TO A 0.5% HCL SOLUTION AT ROOM TEMPERATURE. IT WAS DETERMINED THAT BECAUSE THE BUILDING INTERIOR WAS UNDER NEGATIVE PRESSURE, AND ALSO BECAUSE OF PREVAILING ATMOSPHERIC CONDITIONS, THE EXHAUST DUCT CONTENTS WAS FORCED BACK INTO THE WORK AREA. FIVE EMPLOYEES WERE EXPOSED TO THE KOH VAPOR/MIST. THEY WERE HOSPITALIZED OVERNIGHT AND WERE TREATED WITH OXYGEN. THEY WERE DIAGNOSED WITH UPPER RESPIRATORY IRRITATION AND LUNG CONGESTION. THE FIVE EMPLOYEES ALL RETURNED TO WORK THE FOLLOWING WEEK. AS A RESULT OF THE INCIDENT AN ALARM HAS BEEN PLACED ON THE HOOD, ALTHOUGH NO SUCH ALARM IS REQUIRED BY OSHA. A BACK-UP EXHAUST IS ALSO BEING CONSIDERED.

Keywords: RESPIRATORY, LUNG, VENTILATION, INHALATION, CHEMICAL VAPOR, TOXIC FUMES

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106702293 Hospitalized injury Other Occupation not reported
2 106702293 Hospitalized injury Other Occupation not reported
3 106702293 Hospitalized injury Other Occupation not reported
4 106702293 Hospitalized injury Other Occupation not reported
5 106702293 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.