Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14408157 - Employee killed when struck by flying flange

Accident Summary Nr: 14408157 -- Report ID: 0626700 -- Event Date: 03/12/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12357020203/13/199735930International Cylinder Manufacturing Inc

Abstract: On or about April 12, 1997, Employee #1 and a coworker were running a hydraulic pressure test procedure on a motion compensatory cylinder when the flange blew off. It struck Employee #1 in the head, killing him instantly. Approximately 10 bolts had been used to secure the 2.44-in.-thick flange to the cylinder, but the bolts had not been inspected to determine if they were the correct length to secure the part. The bolts were stripped away when the flange blew. The length of thread going into the flange head was 1.375 in. Eight of the 10 bolts were 2.75 in., 2.625 in., or 2.5 in.; the length of all bolts should have been approximately 3.81 in.

Keywords: HEAD, CYLINDER, UNSECURED, WORK RULES, STRUCK BY, FLYING OBJECT, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123570202 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.