Accident Report Detail

Accident Summary Nr: 14387633 - Ten employees exposed to carbon monoxide from forklifts

Accident Summary Nr: 14387633 -- Report ID: 0524200 -- Event Date: 04/08/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10009945604/08/198720510Newly Weds Foods Inc.

Abstract: During the second shift on April 4, 1987, Employees #1 through #10 were working in the day blending department. Three propane-powered forklift trucks were being operated there, even though the general dilution ventilation system had apparently been turned off by an undetermined employee. Employees #1 through #10 suffered headache, nausea, dizziness, and chest pain, and Employees #1 through #3, #5, and #7 through #9 were transported to local hospitals. They were found to have an average carboxyhemoglobin level of 23.6 percent. This corresponds to an airborne concentration of approximately 100 ppm for an 8-hour exposure, which exceeds OSHA's personal exposure level (PEL) of 50 ppm. The use of two or three forklift trucks for material handling is common for this type of industrial operation.

Keywords: VENTILATION, HEADACHE, WORK RULES, INHALATION, NAUSEA, INDUSTRIAL TRUCK, EXHAUST FUMES, CARBOXYHEMOGLOBIN, POISONING, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 100099456 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
4 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 100099456 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
6 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
7 100099456 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
8 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
9 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported
10 100099456 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.