Accident Report Detail

Accident Summary Nr: 14367775 - Several employees injured when scaffold collapses

Accident Summary Nr: 14367775 -- Report ID: 0523400 -- Event Date: 02/07/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12204297102/07/199617410Superior Masonry Builders Inc.

Abstract: At approximately 11:30 a.m. on February 7, 1996, Employees #1 through #5, bricklayers, and Employees #6 and #7, laborers, were veneering a concrete block wall with brick while standing on the platform of a 16 tower (8 pairs) Morgan scaffold approximately 24 ft from the ground. The scaffold towers were erected to a height of 27 ft in three 9 ft sections. Seven masonry wall anchors were placed in the veneer portion of the wall 16 ft above the ground at 15 ft horizontal intervals (every other tower). Because of a lack of stiff arm braces, only five of the seven anchors were used, leaving four towers at the north end unanchored. Three anchors on the north end were concrete block to brick wall ties using #6 wire and were not designed for this type of application. The typical notched flat stock anchors were not installed properly because regular non-cut nails were used. The employer also failed to anchor every tower at 9 ft vertical intervals as required for enclosed scaffolds. The working platform was enclosed with a plastic canopy open to the wall on the west end of the scaffold. As the platform was raised above the offset roof eave line, a 32 mph wind gust from the west-southwest tipped the north tower east. As the tower fell, it struck thirteen other towers that all collapsed. All five anchors in use were pulled from the wall. Employees #1 through #7 fell to the ground, sustaining fractures to the head, face, pelvis, ankle, knee, and arm, as well as lacerations and bruises. They were hospitalized.

Keywords: ANCHOR, FRACTURE, HIGH WIND, UNSECURED, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, BRACING, TOWER, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122042971 Hospitalized injury Cut/Laceration Brickmasons and stonemasons
2 122042971 Hospitalized injury Cut/Laceration Brickmasons and stonemasons
3 122042971 Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
4 122042971 Hospitalized injury Fracture Construction trades, n.e.c.
5 122042971 Hospitalized injury Fracture Construction trades, n.e.c.
6 122042971 Hospitalized injury Fracture Brickmasons and stonemasons
7 122042971 Hospitalized injury Fracture Brickmasons and stonemasons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.