Accident Report Detail
Accident Summary Nr: 14348361 - TANK RUPTURED AND SPEWED HOT LIQUOR ON EMPLOYEES
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1961432 | 02/07/1985 | 1742 | 0 | Howell Insulation Co., Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 1219401 | 02/08/1985 | 1791 | 0 | Mcabee Construction Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 1219302 | 02/07/1985 | 1541 | 0 | Beloit Pulping Systems |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 1219294 | 02/08/1985 | 1721 | 0 | John T. Friis Company |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 1219385 | 02/08/1985 | 1731 | 0 | Bailey Controls Company |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 1961440 | 02/07/1985 | 1731 | 0 | Haines City Electric Inc. |
Abstract: ON FEBRUARY 4, 1885, AT 9:30 AM, THE PRIME CONTRACTOR WAS RUNNING AN EXPERIMENT, BY COMPUTER, ON THE #10 DIGESTER. A SUBCONTRACTOR AND A PLANT EMPLOYEE WERE ASSISTING. A BLOW LINE PLUGGED. AIR AND STEAM FAILED TO CLEAR THE LINE. A SUBCONTRACTOR EMPLOYEE PULLED THE CARDS FROM THE BAILEY CONTROL NET 90 DISTRIBUTIVE CONTROL SYSTEM (COMPUTER). REMOVAL OF THE CARDS CAUSED THREE VALVES TO OPEN. THE OPENING OF TWO OF THESE VALVES CAUSED THE WARM LIQUOR ACCUMULATOR TANK TO OVERPRESSURIZE. THE TANK RUPTURED AT THE TOP WELDED SEAMS, BLOWING HOT BLACK LIQUOR ONTO EMPLOYEES #1 THROUGH #9, WHO WERE WORKING IN PROXIMITY TO THE TANK. THE CARDS SHOULD NOT HAVE BEEN PULLED AND THEN PLUGGED BACK IN WITHOUT SETTING THE DEFAULT VALVE FOR "CLOSED". CONTRACTOR PERSONNEL WORKING ON OR AROUND THE TANK SHOULD HAVE BEEN NOTIFIED OF THE EXPERIMENT AND INSTRUCTED TO TAKE THE REQUIRED ACTIONS TO PROTECT THEMSELVES.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1961432 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 2 | 1219401 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 3 | 1219401 | Fatality | Burn(Chemical) | Occupation not reported | ||
| 4 | 1219302 | Occupation Not Listed | ||||
| 5 | 1219294 | Hospitalized injury | Other | Occupation not reported | ||
| 6 | 1219294 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 7 | 1219294 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 8 | 1219294 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 9 | 1219385 | Occupation Not Listed | ||||
| 10 | 1961440 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 11 | 1961440 | Hospitalized injury | Burn(Chemical) | Occupation not reported |