Accident Summary Nr: 14339618 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 14339618 -- Report ID: 0453710 -- Event Date: 08/23/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
1854469208/24/198916230Yates Construction Company, Inc.

Abstract: AN EMPLOYEE WAS STANDING ON THE GROUND, HOLDING A SECTION OF 12-INCH-DIAMETER DUCTILE IRON PIPE THAT WAS SUSPENDED FROM THE BUCKET OF A CATERPILLAR TRACKED BACKHOE (MODEL NO. 225). A 13.2-KILOVOLT OVERHEAD POWER LINE WAS LOCATED 14 FEET, 8 INCHES ABOVE THE GROUND OVER THE WORK LOCATION. THE BOOM OF THE BACKHOE CONTACTED THE OVERHEAD LINE, ELECTROCUTING THE EMPLOYEE.

Keywords: BACKHOE BOOM, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA, BACKHOE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18544692 Fatality Electric Shock Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.