Accident Summary Nr: 14337232 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC ROTO-ROOTER

Accident Summary Nr: 14337232 -- Report ID: 0419700 -- Event Date: 08/02/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10136293708/04/198876990San Jose Plumbing Company

Abstract: A PLUMBER'S HELPER WAS ASSISTING HIS EMPLOYER IN OPENING A CLOGGED SEWER PIPE IN AN APARTMENT COMPLEX. HE WAS STANDING IN A SHALLOW EXCAVATION TO PULL FLEXIBLE COIL FROM THE ROTATING BASKET OF A ROOTER-TYPE SEWER MACHINE AND FORCE IT ALONG THE SEWER LINE. THE EMPLOYER HAD BEEN OPERATING THE MACHINE BY MEANS OF ITS CONTROL BOX, WHICH WAS ATTACHED TO THE MACHINE THROUGH A LONG CORD. WHEN THE EMPLOYER PLACED THE CONTROLLER DOWN AND WENT AROUND THE BUILDING TO CHECK PROGRESS AT A CLEAN OUT OPENING, THE EMPLOYEE PICKED UP THE CONTROLLER AND BEGAN TO OPERATE THE MACHINE HIMSELF. BECAUSE OF THE EMPLOYEE'S POSITION IN THE EXCAVATION, THE CONTROLLER CORD BECAME ENTANGLED WITH THE ROTATING BASKET, DAMAGING THE INSULATION AND EXPOSING THE CONDUCTORS. THE ENERGIZED CONDUCTORS CONTACTED THE METAL BASKET, ENERGIZING IT AND THE ATTACHED FLEXIBLE METAL COIL. THE EMPLOYEE, WHO WAS STILL HOLDING THE COIL, WAS ELECTROCUTED. THE EMPLOYEE HAD BEEN WORKING AT THIS JOB FOR 8.5 MONTHS AND HAD HAD NO SAFETY TRAINING.

Keywords: E GI III, ELECTRICAL, ELECTROCUTED, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101362937 Fatality Electric Shock Plumber, pipefitter and steamfiter apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close