Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14326946 - 4 EMPLOYEES BURNED WHEN COAL TAR VAPORS IGNITED

Accident Summary Nr: 14326946 -- Report ID: 0317500 -- Event Date: 02/08/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
73858302/08/198834790Durabond Company

Abstract: EMPLOYEES #1-4 WERE WORKING AROUND A COAL TAR PITCH TANK THAT CONTAINED COAL TAR PITCH HEATED TO ABOUT 450 DEGREES FAHRENHEIT. THE MATERIAL PRODUCES EXTREMELY FLAMMABLE VAPORS AT THAT TEMPERATURE. THE TANK HAS A LARGE COVER ON IT WITH A DOOR TO ADD COAL TAR PITCH. THE COVER IS NOT BOLTED OR OTHERWISE SECURED TO THE TANK. A 2 INCH STEEL PIPE IS PUMPED FULL OF COAL TAR PITCH FROM THE BOTTOM OF THE TANK. THE PIPE RUNS 65 FEET IN BOTH DIRECTIONS AND RETURNS TO A CONNECTING PART ON THE COVER. EMPLOYEES #1-4 WERE CHANGING THE SECTION OF PIPE THAT GOES INTO THE COVER. THE INLET WAS OPEN. EMPLOYEE #1 INADVERTENTLY PASSED A TORCH ACROSS THE INLET. THE VAPORS IGNITED. THEY WERE ALL STANDING NEXT TO THE TANK AND WERE BURNED BY FLAMES SHOOTING OUT FROM BETWEEN THE TANK AND ITS COVER.

Keywords: BURN, COAL TAR PITCH, FLAMMABLE VAPORS, WORK RULES, FIRE, TORCH, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.