Accident Summary Nr: 14296180 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

Accident Summary Nr: 14296180 -- Report ID: 0352440 -- Event Date: 11/19/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
285659911/27/198517710M & B Concrete Service Incorporated
Inspection NrDate OpenedSICNAICSEstablishment Name
285657311/21/198517910R. E. Linder Steel Erection Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
285656511/21/198517910Rod-Buster Service Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
285658111/27/198542130Vimco Incorporated

Abstract: Some employees were using a Link-Belt truck crane (Model No. HC218, Serial No. 18HB151) to unload concrete reinforcement steel from a flatbed truck. The crane had a main boom that was 36.7 meters (120 feet) long with a 13.7-meter-long (45-foot-long) jib. One of the employees was standing on the bed of the truck, rigging the skids of material to be hoisted. He asked a coworker on the ground at the rear of the truck for another sling. The coworker handed him the choker-type sling that was attached to the load block. As the employee took the sling, the load line of the crane contacted a 7620-volt overhead power line located 9.6 meters (31.7 feet) above the ground. Both employees received electric shocks and sustained burns to their hands. They were hospitalized for their injuries.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BURN, LOAD LINE, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2856599 Occupation Not Listed
2 2856573 Hospitalized injury Electric Shock Crane and tower operators
3 2856565 Hospitalized injury Electric Shock Structural metal workers
4 2856581 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.