Accident Summary Nr: 14235303 - ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Accident Summary Nr: 14235303 -- Report ID: 0626300 -- Event Date: 07/10/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10230778207/12/198935360Stewart-Wattley Material Handling Equipment Co.

Abstract: AN EMPLOYEE WAS CHECKING OUT A CRANE. HE HAD CONNECTED INSULATED ALLIGATOR CLIPS ON A 480-VOLT, THREE-PHASE EXTENSION CORD SET TO THE BARE CONDUCTOR ENDS FOR THE CRANE. HIS ASSISTANT HAD PLUGGED THE CORD SET INTO A RECEPTACLE AND REPORTED TO THE EMPLOYEE AND TO THE ASSISTANT CHIEF ENGINEER THAT THE DISCONNECT WAS IN THE OFF POSITION. THE FIRST EMPLOYEE THEN TOOK TWO OF THE LEADS, ONE IN EACH HAND. HE WAS HOLDING THEM BY THE UNINSULATED PORTIONS TO SEPARATE THEM BEFORE THE CIRCUIT WAS ENERGIZED. UNFORTUNATELY, THE ASSISTANT HAD APPARENTLY CONFUSED THE OFF POSITION WITH THE ON POSITION ON THE DISCONNECT, AND THE CORD SET WAS ENERGIZED. THE EMPLOYEE HOLDING THE LEADS WAS ELECTROCUTED.

Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, CORD SET, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELECTRIC CONDUCTOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102307782 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close