Accident Summary Nr: 14225064 - EMPLOYEE'S FINGERS AMPUTATED WHEN CAUGHT IN POWER PRESS

Accident Summary Nr: 14225064 -- Report ID: 0355119 -- Event Date: 07/21/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
331697307/21/198734250The Disston Company

Abstract: At approximately 7:30 a.m., on April 24, 1987, Employee #1 was being trained to operate a full revolution Minster power press Serial Number 10-4-4585. The power press was operated by a foot control and equipped with pull back devices. The supervisor of Employee #1 adjusted the pull back devices to fit Employee # 1. When placing a part in the press, Employee # 1 pushed the foot switch and the press cycled. The pull back device of left hand did not pull the hand out, causing partial amputation of four fingers on the left hand. The inspection of the press conducted after the accident found that the bolt holding back frame to the press broke. This allowed the frame to drop or pull away from the press, making the left pull back device too long to pull the hand out of the dies.

Keywords: PULL BACK DEVICE, DIE, AMPUTATED, POWER PRESS, FINGER, FOOT CONTROL, BOLT, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3316973 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close