Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 142145.015 - Employee amputates fingertip when pneumatic cylinder returns

Accident Summary Nr: 142145.015 -- Report ID: 0418300 -- Event Date: 12/15/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1569778.01512/20/2021333517Franklin Manufacturing, Inc.

Abstract: At 3:00 p.m. on December 15, 2021, an employee was testing the operation of a pneumatic cylinder and gears in a centering device prior to installing the housing cover. The employee placed his hand on the device assembly to steady it during operation and applied air to the steel cylinder. The cylinder returned with sufficient force to amputate his left pinky fingertip to the distal joint. The employee was treated without hospitalization.

Keywords: Air Pressure, Amputated, Amputation, Assembling, Assembly Line, Engineering Controls, Finger, Fingertip, Gear, High Pressure, Inexperience, Insufficient Supervision, Lack of Engineering Controls, Lack of Work Procedures, Misjudgment, Misjudgment of Hazardous Situation, Partial Amputation, Pneumatic, Pneumatic cylinder, Pneumatic equipment, Supervision, Testing, Training

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1569778.015 30 M Non Hospitalized injury Assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.