Accident Report Detail
Accident Summary Nr: 14214027 - One employee killed, others injured when unit explodes
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 105522270 | 05/28/1988 | 1796 | 0 | Murphy Welding & Crane Service |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 105522288 | 05/28/1988 | 1541 | 0 | Norman Construction Company Inc |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 105522296 | 05/28/1988 | 1711 | 0 | Allied Piping Co |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 105522270 | 05/28/1988 | 1796 | 0 | Murphy Welding & Crane Service |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 105522072 | 05/31/1988 | 3069 | 0 | Baxter Pharmaseal Laboratories |
Abstract: This accident occurred in the sterilization area where two 45 ft long by 4 ft 10 in. wide by 6 ft 6 in. high sterilization units were situated side by side. The construction crews were replacing a door on the unloading end of unit #1, using a torch powered by MAPP (methylacetylene propadiene) gas. Grinding was also being done. A few seconds after the door on unit #2 was opened an explosion occurred at unit #2. Several employees were directly in front of or near the exploding unit. Other employees were at unit #1. Employees #1 through #7 sustained burns and/or other injuries. Employee #8 died. The fuel sources were ethylene oxide (ETO), MAPP, propane, and gasoline. The gasoline was in a small can and the propane was in a cylinder on a forklift. Neither is considered to have caused the explosion. A small leak was found between the MAPP cylinder and the regulator, but it was not considered to have been large enough to have caused the explosion. The explosion apparently was caused by the ETO that was still in unit #2 and which ignited when unit #2 was opened.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 105522270 | Non Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. | ||
| 2 | 105522270 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, n.e.c. | ||
| 3 | 105522288 | Hospitalized injury | Burn/Scald(Heat) | Broadcast equipment operators | ||
| 4 | 105522296 | Hospitalized injury | Burn/Scald(Heat) | Plumbers, pipefitters and steamfitters | ||
| 5 | 105522296 | Fatality | Burn/Scald(Heat) | Plumbers, pipefitters and steamfitters | ||
| 6 | 105522270 | Hospitalized injury | Strain/Sprain | Construction trades, n.e.c. | ||
| 7 | 105522072 | Hospitalized injury | Burn/Scald(Heat) | Engineers, n.e.c. | ||
| 8 | 105522072 | Hospitalized injury | Burn/Scald(Heat) | Engineers, n.e.c. |