Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14204465 - EXPOSED TO TOXIC FUMES FROM CHEMICAL REACTIONS

Accident Summary Nr: 14204465 -- Report ID: 1054194 -- Event Date: 06/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1503347506/27/198534710All American Plating Service Inc Dba

Abstract: EMPLOYEE #1 ACCIDENTALLY ADDED 55 GALLONS OF CONCENTRATED SULFURIC ACID (93%) TO 30 GALLONS OF DILUTE HYDROCHLORIC ACID (31%) IN AN OUTDOOR STRIPPING TANK. A VIOLENT REACTION ENSUED, CAUSING THE RELEASE OF TOXIC GASES. EMPLOYEE #1 THEN TRIED TO STABILIZE THE SITUATION BY ADDING WATER TO THE TANK. EMPLOYEE #3 WAS FIVE FEET FROM THE TANK, EMPLOYEE #2, 75 FEET AND EMPLOYEE #7, 50 FEET. EMPLOYEES #4, 6, 8 AND 9 TRIED TO NEUTRALIZE THE ACID BY THE ADDITION OF SODA ASH (400 POUNDS). THIS RESULTED IN A SECOND RELEASE OF GASES. THE EMPLOYEES SUFFERED PULMONARY IRRITATION AND VIOLENT COUGHING. THE CAUSAL FACTORS WERE: A LACK OF TRAINING IN HANDLING CHEMICALS, THE FAILURE TO USE ACID PUMPS, FAILURE TO WEAR PERSONAL PROTECTIVE EQUIPMENT AND THE FAILURE TO READ THE LABEL ON THE CHEMICAL CONTAINER.

Keywords: RESPIRATORY, PPE, INHALATION, CHEMICAL REACTION, TOXIC FUMES, UNTRAINED, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15033475 Hospitalized injury Other Occupation not reported
2 15033475 Hospitalized injury Other Occupation not reported
3 15033475 Hospitalized injury Other Occupation not reported
4 15033475 Hospitalized injury Other Occupation not reported
5 15033475 Hospitalized injury Other Occupation not reported
6 15033475 Hospitalized injury Other Occupation not reported
7 15033475 Hospitalized injury Other Occupation not reported
8 15033475 Hospitalized injury Other Occupation not reported
9 15033475 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.