Accident Summary Nr: 121293.015 - Employee's finger is amputated when glove is caught by bands

Accident Summary Nr: 121293.015 -- Report ID: 0950632 -- Event Date: 06/25/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1425620.01508/23/2019332322Cp Manufacturing, Inc.

Abstract: At 01:00 a.m. on June 25, 2019, an employee was serving as a newly assigned bandsaw operator using an HE&M Twister Automatic Band Saw, Serial Number 794501, to cut 2-foot lengths of 4-inch by 4-inch rectangular metal tubing. The employee was in the process of cutting the metal tubing with the bandsaw when the blade caught the MaxiFlex glove, model number 24-845 CAT II, on the left hand, drawing it into the blade. The employee sustained an amputation to the left index finger at the proximal interphalangeal joint which included bone loss. The employee was treated and released at Sharp Memorial Hospital on June 25, 2019. At 08:15 a.m. on June 25, 2019, the employer reported the incident incompliance with CSHO requirements. At 09:10 a.m. on August 23, 2019, CSHO arrived on site to begin their investigation and a CCR T8 4184(a) citation for not guarding the point of operation of a machine.

Keywords: Amputation, Bandsaw, Blade, Caught By, Caught In, Cutting, Finger, Glove, Machine operator, Metal Pipe, Operator, Point Of Operation, Saw, Sawblade, Sheet Metal, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1425620.015 30 M Non Hospitalized injury Sawing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close