Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 118543.015 - Employee sustains crushing injuries to hand when caught betw

Accident Summary Nr: 118543.015 -- Report ID: 0523900 -- Event Date: 07/25/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1420077.01508/01/2019311821Best Maid Cookie Company

Abstract: At 9:45 p.m. on July 25, 2019, a quality assurance employee was performing a pre-operation visual inspection of in-service (running) equipment located in the Preform-A area of the cookie department to ensure the line was clean of all residual food product. During the visual inspection, the employee noticed a small amount of dough left in the Drop Machine. The employee reached into the running Drop Machine to wipe off the excess product and her right hand got caught between two unguarded rollers. A coworker within close proximity immediately activated the Drop Machine's emergency stop button. Another coworker (maintenance worker) was able to free the employee's right hand from the equipment by reversing the polarity of the Drop Machine's motor. The employee sustained crushing injuries to the right hand. The employee was transported offsite by local emergency medical services and hospitalized due to the extent of fracture and laceration injuries sustained to her right hand.

Keywords: Caught Between, Cleaning, Crushed, Crushing, Emergency Stop, Food processing, Fracture, Hand, Inspecting, Inspection, Laceration, Nip Point, Reach, Reaching, Residual , Reverse Polarity, Roller--Mach/Part, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1420077.015 23 F Hospitalized injury Quality Assurance Inspector

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.