Accident Summary Nr: 1000710 - Employee in coma after ladder falls into air shaft

Accident Summary Nr: 1000710 -- Report ID: 0418200 -- Event Date: 09/21/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10901098309/21/199217910Park Place Steel Construction, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10947223309/21/199251420Beers Construction Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10947222509/30/199217420Chandler Interiors, Inc.

Abstract: At 3:00 p.m. on September 18, 1992, Employee #1 was using an aluminum extension ladder to descend 12' 9" from a roof line to the grating on which the ladder rested. Employee #1 was on the third or fourth rung when the grating gave way and he fell approximately 29 to 30 ft into an air shaft that was 20 1/2 ft deep by 15 ft long by 4 ft wide. He suffered severe head injuries, which required brain surgery and hospitalization, and remains in an induced coma. The air shaft was covered by standard grating supported by an angle iron that was anchored with two red head bolts that appeared to be approximately 1/2 in. in diameter. The bolts sheared off, causing the angle iron grating and the ladder, which was not secured at the top, to fall into the shaft. Prior to being placed at the location from which it fell, the ladder had been used near the center of the roof and extended through an area not yet decked; the ladder was tied off at that location. When the steel crew needed to complete the decking, the ladder was moved to the northwest corner and placed on the grating with its top wedged against the roof edge which met with a wall that extended from the roof at a 90 degree angle. Causal factors include the ladder being placed on an unstable surface and not being tied off at the top. The investigation revealed that employees of the general contractor, employees of the drywall crew, and the steel workers had all used the ladder while it was in that position.

Keywords: BOLT, SHEARED, DESCENDING, FALL, UNSECURED, METAL LADDER, EXTENSION LADDER, CONSTRUCTION, UNSTABLE SURFACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109010983 Hospitalized injury Concussion Occupation not reported
2 109472233 Occupation Not Listed
3 109472225 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.