Inspection Detail
Inspection: 1360007.015 - 317722446 - Green Acres K-9 Resort Inc
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
317722446 - Green Acres K-9 Resort Inc
26075 Se Highway 212
Boring, OR 97009
Mailing Address:
26075 Se Highway 212, Boring, OR 97009
Union Status: NonUnion
SIC:0752
NAICS: 812910/Pet Care (except Veterinary) Services
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/14/2019
Emphasis:
Case Closed: 07/17/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1400266 | Yes | |
| Complaint | 1395576 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $200 | $0 | $0 | $0 | $0 | $200 |
| Current Penalty | $200 | $0 | $0 | $0 | $0 | $200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19101200 E01 | 02/12/2019 | 03/15/2019 | $100 | $100 | $0 | Z - Issued | ||
| 2. | 01001B | Serious | 19101200 G01 | 02/12/2019 | 03/15/2019 | $0 | $0 | $0 | Z - Issued | ||
| 3. | 01001C | Serious | 19101200 H03 IV | 02/12/2019 | 03/15/2019 | $0 | $0 | $0 | Z - Issued | ||
| 4. | 01002A | Serious | OAR 437-002-0134(1)(A) | 02/12/2019 | 03/15/2019 | $100 | $100 | $0 | Z - Issued | ||
| 5. | 01002B | Serious | OAR 437-002-0161(5)(A) | 02/12/2019 | 03/15/2019 | $0 | $0 | $0 | Z - Issued | ||
| 6. | 02003 | Other | 19101200 H03 II | 02/12/2019 | 03/15/2019 | $0 | $0 | $0 | Z - Issued |
Inspection: 1360007 - Playmade Products
Inspection Information - Office: Houston North Area Office
Site Address:
Playmade Products
20001 Oil Center Blvd
Houston, TX 77090
Mailing Address:
8323 Bojack, Houston, TX 77040
Union Status: NonUnion
SIC:3599
NAICS: 0
Inspection Type: Accident
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/24/1984
Emphasis:
Case Closed: 08/28/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360574925 |
Investigation Summary
The owner of a company that designed, built, and installed a Pentex overhead crane at a remote location arrived at that site to repair electrical problems in a pendant control for the crane. He requested that the control remain energized so that he could check the wiring. He walked down the rail on the south side of the shop to get to the bridge of the crane. He then went out on one of the bridge girders, reached out 600 to 900 millimeters, and opened the electrical box. There were no guardrails on the bridge girders or rails. In addition, the company owner was not using personal fall arrest equipment. While he was working on the box, he apparently contacted an energized part of the circuit. He froze to the circuit until the main circuit breaker for the crane tripped, and then he fell about 9.1 meters to the floor. He died of electrocution.
Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, ELEC CIRC PART--MISC, FALL, FALL PROTECTION, ELECTRICAL BOX
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1360007 | Fatality | Electric Shock | Chief exec's & gen'l administrators, public admin. |
Back to Top
Translate