Powered by GoogleTranslate

Inspection Detail

Inspection: 308682996 - Vala'S Pumpkin Farm And Fall Festival Inc.

Inspection Information - Office: Omaha Area Office

 

Inspection Nr: 308682996
Report ID: 0728900
Date Opened: 09/25/2006

Site Address:
Vala'S Pumpkin Farm And Fall Festival Inc.
12102 S. 180th Street
Gretna, NE 68028

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7999

NAICS: 713990/All Other Amusement and Recreation Industries


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/13/2006


Related Activity
Type Activity Nr Safety Health
Referral 200057362 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $2,250 $0 $0 $0 $0 $2,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 09/27/2006 10/16/2006 $675 $1,350 $0 I - Informal Settlement  
2. 01002 Serious 19100305 E01 09/27/2006 10/16/2006 $900 $1,800 $0 I - Informal Settlement  
3. 01003A Serious 19101200 E01 09/27/2006 10/16/2006 $675 $1,350 $0 I - Informal Settlement  
4. 01003B Serious 19101200 H 09/27/2006 10/30/2006 $0 $0 $0 -  
5. 02001 Other 19040029 A 09/27/2006 10/30/2006 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200052751
Event: 09/23/2006
Employee Is Burned While Lighting Roaster

At approximately 3:20 p.m. on September 23, 2006, Employee #1 was attempting to light a propane-gas-fueled turkey leg roaster with a long-handled lighter. The roaster had been custom built by a local heating and air conditioning contractor and used a water heater control module for burner control. Employee #1 activated the pilot primer valve, which emits propane gas from the pilot located in the center of the main burner. He held the valve open, which allowed propane to build up within the base of the roaster. Employee #1 then tried unsuccessfully to reach the pilot through a small hole in the front of the unit. The accumulated gas reached the flame of the lighter and ignited. Employee #1 was hospitalized with first- and second-degree burns on his left hand, arm, and head. The roaster had no manufacturer's data and there were no written instructions for its use. The normal lighting procedure requires an employee to reach into the roaster through the oven area, where the burner is easily accessible, rather than through the hole Employee #1 attempted to use. The investigation revealed that Employee #1 was not trained in this normal lighting procedure.

Keywords: BURN, PILOT LIGHT, HEAD, FOOD PREPARATION, OVEN, WORK RULES, LIGHTING, PROPANE, UNTRAINED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308682996 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close