Powered by GoogleTranslate

Alphabetic Index of Sampling and Analytical Methods - H

Substance CAS Number(s) Instrument Sampler
Hafnium [ID-121] Fully Validated 7440-58-6 AA MCEF
Halothane [29] Fully Validated 151-67-71 GC/FID CSC
Halothane [103] Fully Validated 13838-16-9 GC/FID Anasorb CMS or Anasorb 747
Heptachlor [PV2029] Partially Validated 76-44-8 GC/ECD OVS-2
1,6-Hexamethylene Diisocyanate [42] Fully Validated 822-06-0 HPLC/FL GFF coated with 12PP
1,6-Hexamethylene Diisocyanate [W4002] Fully Validated 822-06-0 HPLC/FL Ghost Wipes (dry)
Hexamethylene Diisocyanate Biuret [PV2030] Partially Validated 4035-89-6 HPLC/FL GFF coated with 12PP
1,6-Hexamethylene Diisocyanate Homopolymer [PV2125] Partially Validated 28182-81-2 HPLC/FL GFF coated with 1-2PP
1,6-Hexanediol Diacrylate [PV2133] Partially Validated 13048-33-4 GC/FID Chromosorb 106
2-Hexanone [PV2031] Partially Validated 591-78-6 GC/FID CSC
Hexavalent Chromium [ID-215 Version 2] Fully Validated 18540-29-9 IC/UV-vis PVC filter (or binderless quartz fiber filter coated with sodium hydroxide for chromium plating only)
Hexavalent Chromium [W4001] Fully Validated 1333-82-0 IC PVC or binderless quartz fiber filter
Hexavalent Chromium [ID-215] Fully Validated 18540-29-9 IC/UV-vis PVC filter
Hexavalent Chromium [ID-103] Fully Validated (Superseded by ID-215) 18540-29-9 Polarography PVC
Hexavalent, Chromium [ID-103] Backup 18540-29-9    
Hexone [1004] Fully Validated 108-10-1 GC/FID CSC, SKC 575-002 or 3M 3520
Hexylene Glycol [PV2101] Partially Validated 107-41-5 GC/FID CSC
HMX [PV2032] Partially Validated 2691-41-0 HPLC/UV GFF
Hydrazine [20] Fully Validated 302-01-2 HPLC/UV GasChrom R coated with Sulfuric Acid
Hydrazine [108] Fully Validated 302-01-2 HPLC/UV GFF coated with Sulfuric Acid
Hydrazoic Acid [ID-211] Fully Validated 7782-79-8 IC/UV Silica Gel coated with Sodium Hydroxide
Hydrogen Bromide [ID-165SG] Partially Validated 10035-10-6 IC Silica Gel
Hydrogen Chloride [ID-174SG] Partially Validated 7647-01-0 IC Silica Gel
Hydrogen Cyanide [1015] Fully Validated 74-90-8 IC/Electrochemical Detector SKC ULTRA II Passive Sampler
Hydrogen Cyanide [ID-120] Fully Validated 74-90-8 ISE-CN MCEF followed by NaOH impinger
Hydrogen Fluoride [ID-110] Fully Validated   ISE MCEF
Hydrogen Peroxide [1019] Fully Validated 7722-84-1 Spectrophotometer titanium oxysulfate coated quartz filters
Hydrogen Peroxide [ID-006] Partially Validated 7722-84-1 Spectrophotometer Bubbler with Titanium Oxysulfate
Hydrogen Peroxide [ID-126SG] Partially Validated 7722-84-1 Differential Pulse Polarography Impinger with Titanium Oxysulfate
Hydrogen Sulfide [1008] Fully Validated 7783-06-4 IC/glass sampler containing: untreated GFF sodium carbonate coated GFF;silica gel, two sections (200/200 mg) coated with silver nitrate
Hydrogen Sulfide [ID-141] Fully Validated 7783-06-4 Polarography Whatman 4 coated with Silver Nitrate
Hydrogen Sulfide [ID-141] Backup 7783-06-4    
Hydroquinone [PV2094] Partially Validated 123-31-9 GC/FID XAD-7 coated with Phosphoric Acid
2-Hydroxypropyl Acrylate [PV2078] Partially Validated 999-61-1 GC/FID CSC coated with TBC
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close