Powered by GoogleTranslate

Variances in Effect & Interim Orders

Construction

This table is best viewed on tablets, notebooks, or desktop computer screens.

Number Grantee Effective Date Standard(s) Variance Type Federal Register Reference Effective Locations (States) Brief Description
1 Impregilo Healy Parsons Joint Venture (IHP JV)
Anacostia River Tunnel Project
20-Aug-2015 1926.803(e)(5); 1926.803(f)(1); 1926.803(g)(1)(iii); and 1926.803(g)(1)(xvii) Permanent OSHA-2014-0011 DC Allows employers to use alternate means of protection from the provisions of OSHA standards that regulate work in compressed-air environments.
2 Kiewit Power Constructors Co. et al.; (Avalotis Corp.; Bowen Engineering Corporation (merged with Mid-Atlantic Boiler & Chimney, Inc. (formerly Alberici Mid-Atlantic, LLC)); Commonwealth Dynamics, Inc.; Gibraltar Chimney International, LLC; Hamon Custodis, Inc. (formerly Custodis Construction Co., Inc., then Custodis Cuttrell, Inc.); Hoffmann, Inc.; Industrial Access, Inc; International Chimney Corporation; Karrena International Chimney; Kiewit Power Constructors Co.; Marietta Silos, LLC; Matrix SME, Inc. (formerly Matrix Service Industrial Contractors, Inc.); NAES Power Contractors (formerly American Boiler and Chimney Company); Pullman Power, LLC (formerly M. W. Kellogg Co., then Pullman Power Products Corporation); R and P Industrial Chimney Co., Inc.; T.E. Ibberson; & TIC-The Industrial Company) 28-Sep-2013 1926.452 (o)(3); 1926.552 (c)(1) through (c)(4), (c)(8), (c)(13), (c)(14)(i), and (c)(16) Permanent OSHA-2012-0015 All Fed OSHA States Plus: AK, AZ, IN, MD, MN, NV, NM, NC, OR, PR, TN, VA, VT, WY Allows employers to use a rope-guided hoist system during inside or outside chimney construction to raise or lower workers between the bottom landing of a chimney and an elevated work location on the inside or outside surface of the chimney using personnel cages, personnel platforms, and boatswain's chairs.
3 Traylor Bros., Inc. 11-Mar-2016 1926.803(e)(5); 1926.803(f)(1); 1926.803(g)(1)(iii); and 1926.803(g)(1)(xvii) Permanent OSHA-2012-0035 All States Allows employers to use alternate means of protection from the provisions of OSHA standards that regulate work in compressed-air environments.
General Industry
Number Grantee Effective Date Standard(s) Variance Type Federal Register Reference Effective Locations (States) Brief Description
1
  • 3M Co. (formerly Minnesota Mining & Manufacturing Co.) 3M Center
  • St. Paul, MN 55144
10-Mar-1978 1910.106(d)(5)(vi)(b) Permanent 43:9887-88, 3/10/78 SD, MO, TX Allows employer to store flammable and combustible liquids on racks to the heights and under conditions specified in the order.
2
  • Clark Grave Vault Company 375 East Fifth Avenue
  • Columbus, OH 43201
4-Oct-1977 1910.22(c); 1910.23(c)(3) Permanent 42:54028, 10/4/77 OH Allows employer to continue its operation using galvanizing tank having ledges 31 1/2" wide and sides 30" high in lieu of guardrail and toeboard required by standards, provided special conditions specified are followed.
3
  • Frontier Hot-Dip Galvanizing, Inc.
  • 1740 Elmwood Avenue
  • Buffalo, NY 14207
14-Oct-1977 1910.22(c); 1910.23(c)(3) Permanent 42:55291, 10/14/77 NY Allows employer to continue its operation using galvanizing tank having ledges (including the protective angle) 24" wide and sides 30" high in lieu of guardrail and toeboard required by standards, provided special conditions specified are followed.
4
  • International Association of Drilling Contractors & Others
  • 10370 Richmond Ave, Suite 760
  • Houston, TX 77042 USA
17-Oct-1973 1910.27(b)(1)(i), (ii), (iii), and (c)(4) Interim Order 38: 28984-93, 10/18/73 All States Allows specified employers to use ladder safety devices similar to those mentioned in 1910.27(d)(5) in lieu of the required dimensions of rungs, cleats, and clearances of fixed ladders during the operating or maneuvering of specific derricks.
5
  • Keystone Steel and Wire (KSW) Company
  • 7000 S. W. Adams Street
  • Peoria, IL 61641
13-Oct-2010 1910.1025(h)(2)(i); 1910.1018(k)(2) Grant of Permanent Variance OSHA-2010-0011 IL Allows employer to use compressed air to clean floors and other surfaces where lead and arsenic particulates accumulate.
6
  • Metalplate Galvanizing, Inc. (formerly Metalplate & Coatings, Inc.)
  • 500 Selit Drive, S. W.
  • Atlanta, GA 30336
28-Dec-1976 1910.22(c); 1910.23(c)(3) Permanent 41:56410-11, 12/28/76 Atlanta, GA Allows employer to continue operations while using its galvanizing tank having sides 30" high and ledges 32" wide in lieu of guardrail and toeboard required by standards, provided special conditions specified in the order are followed.
7
  • Newport News Shipbuilding
  • 4101 Washington Avenue
  • Newport News, VA 23607
4-Aug-2015 1915.116(i), (j) & (q) Permanent 81 FR 51499, 8/4/2016 VA Allows employer to work under a suspended load during modular ship construction and structural repair provided special conditions specified within the order are followed.
8
  • Nucor Steel Connecticut Incorporated (NSCI)
  • Address: N/A
  • CT
8-April-2016 1910.147(c)(4)(i)
  • Permanent
81 FR 20680, 4/8/16 CT
  • Allows employer to use a modified lockout/tagout system for its roll mills.
9
  • Outfront Media, LLC (formerly CBS Outdoor Systems, Inc., then Gannett Outdoor Companies, then Outdoor Systems, Inc.)
  • 2502 N. Black Canyon Highway
  • Phoenix, AZ 89009
1-Mar-1991 1910.27(d)(l)(ii), (d)(2), and (d)(5) Permanent 56:8801-04, 3/1/91 NJ, CO, TX, MO, CT, IL, AZ Allows employer to use ladder-safety devices in lieu of safety cages to assure the safety of employees climbing fixed ladders at heights over 65 feet from grade, or when the length of a fixed ladder climb is over 50 feet, whichever is less.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.