• Standard Number: 1910.134(d)(1)(ii); 1910.94(a)(5)

January 29, 1999

Mr. Robert I. Leighton
Leighton Associates, Inc.
70-20 Austin St., Suite 115
Forest Hills, NY 11375

Dear Mr. Leighton:

This is in response to your letter dated January 11, addressed to the U.S. Department of Labor, Occupational Safety and Health Administration's (OSHA's) Directorate of Compliance Programs, in which you disagree with OSHA's policy to cite employers when respirators are used in a manner that has not been approved by the National Institute for Occupational Safety and Health (NIOSH). In particular, you have asked why a half-face negative pressure air-purifying respirator cannot be worn underneath a Type CE air-supplied abrasive helmet.

As you already know, our previous letter of February 26, 1996, to David Abrams addressed the same issue. It stated that the combination of a half-face negative pressure air-purifying respirator and a Type CE air-supplied abrasive helmet has not been approved by NIOSH. This is still the case. NIOSH approval for this situation is not, as you suggest, purely academic. There is the potential that the use of these two respirators together could affect the protection factors of each other due to their mutual interference. This interference may not always be obvious. As we stated in the first letter, the only way to determine this for sure would be to submit all respirator components for approval as required by NIOSH. For this reason, we continue to view dual use of respirators as a potential hazard.

We also have an additional concern about employees removing their helmets while still within a contaminated atmosphere. This procedure can expose employees to very high air contaminant levels. It can also contaminate the interior of the helmet and further add to the potential exposure of the employee when the employee re-dons it. The employer must determine why employees are removing their respirators and how this practice can be eliminated safely.

I hope this clarifies OSHA's position on the use of non-approved respirator combinations. If you have any further questions feel free to contact OSHA's Office of Health Compliance Assistance at (202) 693-2190.

Sincerely,

Richard E. Fairfax
Director
Directorate of Compliance Programs


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.