• Standard Number: 1926.152

August 26, 1996

MEMORANDUM FOR:   REGIONAL ADMINISTRATORS

FROM:             MICHAEL G. CONNORS,
                 Deputy Assistant Secretary

SUBJECT:          DOT Approved Gas Cans
We have reviewed the standard addressing the use of safety cans for flammable liquids at construction sites and have determined that the use of Department of Transportation (DOT) approved containers meets the basic intent of the provisions at §1926.152(a)(1). These gas cans are common household items and not generally considered to be a hazard if used properly.

By its terms, §1926.152(a)(1) requires the use of an approved metal safety can (approved by a nationally recognized testing laboratory) for the handling and use of flammable liquids. Further, a safety can by definition is a container with a capacity of 5 gallons or less and equipped with a spring-closing lid and spout cover, a means to relieve internal pressure, and flash-arresting screen. However, we believe that DOT approved containers of 5 gallon capacity or less, although not meeting these requirements, pose very little hazard and meet the basic intent of the standard. Consequently, we have decided to exercise prosecutorial discretion and consider employer use of DOT approved containers of 5 gallon capacity or less for storage, use, and handling of flammable and combustible liquids to be de minimis noncompliance which should not be cited.


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close