• Standard Number: 1910.146

August 11, 1994

MEMORANDUM FOR:         LINDA R. ANKU
                       REGIONAL ADMINISTRATOR

FROM:                   JOHN B. MILES, JR., DIRECTOR 
                       DIRECTORATE OF COMPLIANCE PROGRAMS

SUBJECT:                Request for Interpretation - 1910.146 (c)(1)
                       Initial Evaluation of the Workplace

This is in response to your memorandum of February 1, in which you requested clarification as to which of two different interpretations of the confined spaces standard is correct. We regret the delay in responding to you.

The first interpretation proposed in your memorandum is correct. The intent of the standard is for all employers in General Industry to evaluate their workplaces to determine if they contain any permit-required confined spaces (PRCS).

Since each inspection is different, rigid compliance guidance can not be provided; however, the following citation strategy for the PRCS standard paragraph (c)(1) (requiring employers to initially evaluate their workplaces) is provided.

Where there is a place of employment which has not been initially evaluated, and there is:

Minimal Potential with No Exposure - A facility which has the potential for confined spaces, but has no hazards and does not have employee exposure would be considered to be in de minimis violation. No citation should be issued.

Potential - Employers who have confined spaces, and have the potential for employee(s) to be in the spaces but do not have a hazard characteristic found in the definition of PRCS may be cited for a low-gravity, non-serious violation of the standard.

If you have further questions on this subject please contact Don Kallstrom (202) 219-8031 extension 109.


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.