May 11, 1989

Mr. John M. Hamment Shawe and Rosenthal Sun Life Building Charles Center Baltimore, Maryland 21201

Dear Mr. Hamment:

This is in response to your letter and subsequent telephone conversations with Mr. Anthony Brown of my staff concerning the application of the new construction standard for cranes and derricks to your client, McLean Construction Company.

We have reviewed the issues raised in your request for interpretation of 29 CFR 1926.550(g) and the information obtained during the site visit to a harbor project operated by McLean Construction Company, and reaffirm that the barge mounted cranes/derricks are not exempt from this standard.

Your concerns and questions about the standard (1926.550(q)), are centered on the assumption that barge based cranes are not covered by the standard and cannot be retrofitted because of the uniqueness of the work being done. The following comments should help clear up the questions of applicability and provide a basis for compliance with the standards.

1. Controlled load lowering--Backing the load line down through the gear train is not controlled load lowering because:

a. backing the line down does not stop descent, and

b. backing the line is a procedure, not a system or device on the power train.

2. One Degree Level--The barge may list as much as 5 degrees under ANSI B30.8-1982 Section 8-1.2.2(3). The crane mounted on the barge must be level within l degree and the employer must ensure that the cranes capacity is derated to account for the barges deviation from level.

3. Live Boom--the mechanical set up in use (dog system) is no problem, but the company must ensure that no personnel are being hoisted when the boom angle is changed.

4. Anti-Two-Blocking Devices--The requirements for a positive acting system is necessary because no other approach provides equivalent protection. The Agency has recognized the difficulty that some crane uses/owners have had in acquiring the appropriate-equipment for compliance with the standard and is preparing interim relief from the standard. See attachment.

The Occupational Safety and Health Administration (OSHA) advises employers to take a hard look at their operations and alternatives before they decide that hoisting of personnel by crane is appropriate or really necessary.

Please contact this office if you have any further questions about any of these issues covered above.

Sincerely,

Gerald P. Reidy, Director Office of Construction and Maritime Compliance Assistance


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close