Powered by GoogleTranslate
Standard Interpretations - Table of Contents
• Standard Number: 1910.120(j)

February 1, 1987

Mr. Owen B. Douglas, Jr., C.I.H.
Manager, Health and Safety
SPER Division
Weston Sper
Weston Way
West Chester, PA 19380

Dear Mr. Owen:

This is in response to your letter of January 20 regarding the Occupational Safety and Health Administration's (OSHA) Interim Final Rule for Hazardous Waste Operations and Emergency Response. You requested an interpretation of section (j) of 29 CFR 1910.120 which addresses "Handling drums and containers."

Your questions concern the specifics of operations where opening drums and containers occur, namely: "(a) when a remotely operated drum opening device is actually required and (b) when can prior experience and training allow a drum to be opened using a bung wrench and manual pressure." OSHA's Hazardous Waste Site standard was written to be a performance oriented standard which sets forth the criteria to be met through safe workplace performance oriented goals. As such, specific requirements are not always addressed, rather, the goals of what is meant be accomplished are. Section (j)(2)(vi) states that "Drums and containers shall be opened in such a manner that excess interior pressure will be safety relieved. If pressure cannot be relieved from a remote location, appropriate shielding shall be placed between the employee and the drums or containers to reduce the risk of employee injury."

The employer is responsible for performing the work of drum opening in safe manner; how he accomplishes this goal is not available to him. It is not possible for OSHA to give you the characterization of the wastesite is unknown to us, and the conditions of each worksite vary greatly from site to site. If, as the standard says, pressure cannot be relieved safely from a remote location, then shields are to be used to protect employees from any hazards they may encounter.

If you should have any further questions, you may want to contact the OSHA Regional Office nearest you. The address and telephone number of the OSHA office nearest your office location in West Chester is:

U. S. Department of Labor - OSHA
Gateway Building
Suite 2100


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close