Standard Interpretations - Table of Contents
• Standard Number: 1910.95(c)

January 19, 1982

Mr. Ben F. Ervin
Corporate Safety Enginee
Brutler Manufacturing Company
BMA Tower, Penn Valley Park
Kansas City, Missouri 64141

Dear Mr. Ervin:

Dr. Alice Suter has asked me to respond to your inquiry concerning compliance with the monitoring requirement of the new hearing conservation amendment (29 CFR 1910.95(e)(1)). Please accept my apology for the delay in our response.

The intent of the requirement for workplace noise monitoring is to identify employees who need to be included in the hearing conservation program. Employers have some flexibility in how they achieve this regulatory goal.

Thus, Butler Manufacturing Company may choose to include all workers (regardless of individual noise exposure levels) in the hearing conservation program, as long as all of the other provisions of the standard are followed for each employee.

As your letter indicates, some of these provisions may require some monitoring of the noise levels to assure that workers are adequately protected. For example:

1. Hearing protectors must attenuate employee noise exposure at least to a time-weighted average (TWA) of 90 decibels. (29 CFR 1910.95(m)(2))

2. For employees who have experienced a significant threshold shift, hearing protectors must attenuate employee noise exposures to a TWA of 85 decibels or below. (29 CFR 1910.95(m)(3))

3. Hearing protectors are mandatory for employees who are exposed to a TWA of 85 decibels or greater and who have experienced a significant threshold shift. (29 CFR 1910.95(l)(2)(i))

4. An employee's audiogram record shall include the employee's most recent noise exposure assessment. (29 CFR 1910.95(q)(2)(ii)(f))

We appreciate your bringing this concern to our attention. OSHA is striving to ensure a minimum of interference with the activities of employers, while at the same time ensuring that necessary actions are taken to protect the safety and health of workers. If we can serve you again, we shall be glad to do so.

Sincerely,



Glen R. Williamson
Agency Coordinator of Noise Projects


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close