Violation Detail
Standard Cited: 19100147 C05 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 976792.015
Citation: 02003
Citation Type: Repeat
Abatement Date: 12/03/2014 2
Initial Penalty: $550.00
Current Penalty: $5,285.00
Issuance Date: 11/13/2014
Nr Instances: 1
Nr Exposed: 100
Related Event Code (REC):
Gravity:
Report ID: 0418100
Contest Date:
Final Order: 12/03/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/03/2014 | $5,285.00 | 12/03/2014 | Repeat | |
Penalty | Z: Issued | 11/13/2014 | $550.00 | 12/03/2014 | Repeat |
Text For Citation: 02 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): On or about 6/4/2014, an employee was observed performing maintenance on the welder that was locked out but was not identified with his name as controlling the lock. Tenneco was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(5)(ii)(D), which was contained in OSHA inspection number 523498, citation number 2, item number 1 and was affirmed as a final order on 11/14/2012, with respect to a workplace located at 200 McIntyre Drive, Hartwell, GA.