Violation Detail
Standard Cited: 19170151 B07 Machine guarding.
Inspection Nr: 897965.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 07/20/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/17/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0420300
Contest Date:
Final Order: 06/07/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/07/2013 | $0.00 | 07/20/2013 | Serious | |
Penalty | Z: Issued | 05/17/2013 | $0.00 | 06/20/2013 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1917.151(b)(7): The power supply to machines was not turned off, locked out and tagged out during repair, adjustment, or servicing. On or about March 26, 2013, employees performing maintenance work on the conveyor system did not affix a lockout device to an energy isolating device.