Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 808301.015
Citation: 01006B
Citation Type: Serious
Abatement Date: 08/05/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/18/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0522000
Contest Date: 07/18/2013
Final Order: 06/19/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/19/2015 | $0.00 | 08/05/2013 | Serious | |
Penalty | C: Contested | 07/18/2013 | $0.00 | 08/05/2013 | Serious | |
Penalty | Z: Issued | 06/18/2013 | $0.00 | 08/05/2013 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct periodic or at least annual inspections of the energy control procedures to ensure that the procedures and the requirements are being followed: (a) Periodic or at least annual inspections of the energy control (lockout) procedures were not conducted to ensure that procedures and requirements were being followed on equipment such as, but not limited to, the chemical treatment tanks #1 and #2 mixers/agitators, the aerosol can crusher hydraulic pump motor, etc.