Violation Detail
Standard Cited: 19100027 D03 Scaffolds and rope descent systems.
Inspection Nr: 805362.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 05/28/2013 2
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 05/01/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 05/14/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2013 | $0.00 | 05/28/2013 | Serious | |
Penalty | Z: Issued | 05/01/2013 | $2,800.00 | 05/28/2013 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.27(d)(3): The employer did not ensure that the side rails of a through ladder extended 3 1/2 feet above parapets and landings, omitting the rungs from the extension and having not less than 18 nor more than 24 inches clearance between the rails. (a) In the mechanic shop, the side rails of the fixed ladder did not extend above the landing. Employee(s) were exposed to at least 8-foot fall hazards when using the ladder to access the storage mezzanine.