Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 584358.015
Citation: 02002
Citation Type: Willful
Abatement Date: 03/07/2013 2
Initial Penalty: $70,000.00
Current Penalty: $7,000.00
Issuance Date: 02/08/2013
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A
Gravity: 10
Report ID: 0419700
Contest Date:
Final Order: 02/22/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/22/2013 | $7,000.00 | 03/07/2013 | Willful | |
Penalty | Z: Issued | 02/08/2013 | $70,000.00 | 03/07/2013 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a. On or about August 16, 2012, temporary employees (Remedy Staffing, Inc.) working near equipment being serviced under lockout tagout were not trained about the hazards associated with the equipment and the controls to minimize those hazards.