Violation Detail
Standard Cited: 19260451 H02 II General requirements.
Inspection Nr: 390542.015
Citation: 01006
Citation Type: Serious
Abatement Date: 08/16/2012 2
Initial Penalty: $3,600.00
Current Penalty: $625.00
Issuance Date: 08/09/2012
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0627510
Contest Date: 09/06/2012
Final Order: 01/16/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/16/2013 | $625.00 | 08/16/2012 | Serious | |
Penalty | C: Contested | 12/19/2012 | $3,600.00 | 08/16/2012 | Serious | |
Penalty | Z: Issued | 08/09/2012 | $3,600.00 | 08/16/2012 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 x 1 1/2 inch (2 x 4 cm) wood or equivalent may be used in lieu of toeboards; On or about March 30, 2012 on the east side of the structure, employees were exposed to struck-by hazards while working without headgear beneath other employees on scaffolding that did not have toeboards installed.