Violation Detail
Standard Cited: 19100119 D03 II Process safety management of highly hazardous chemicals.
This violation item has been deleted.
Inspection Nr: 311611081
Citation: 02022A
Citation Type: Willful
Abatement Date: 04/19/2010
Initial Penalty: $70,000.00
Current Penalty: $0.00
Issuance Date: 03/08/2010
Nr Instances: 1
Nr Exposed: 25
Related Event Code (REC):
Gravity: 10
Report ID: 0524700
Contest Date: 03/31/2010
Final Order: 09/27/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 09/27/2018 | $0.00 | Willful | ||
Penalty | Z: Issued | 03/08/2010 | $70,000.00 | Willful |
Text For Citation: 02 Item/Group: 022A Hazard: REFINERY
29 CFR 1910.119(d)(3)(ii): The employer does not document that the equipment in the process complies with recognized and generally accepted good engineering pra ctices: a.BP-Husky Refining, LLC - Oregon, Ohio: The employer does not document the need for over pressure protection on pressure vessels as required by recognized and generally accepted good engineering practices. The Primary Absorber Lean Oil Cooler (PR543586) is not protected by pressure relieving devices that would pre vent the pressure inside the vessel from rising above acceptable limits. Pursuan t to 29 CFR 1903.19, within ten (10) calendar days of the abatement date, the em ployer must submit documentation that it has abated the hazard. In addition, und er 29 CFR 1903.19(e), the employer must submit an abatement plan describing the actions it is taking to ensure that it is in compliance with the standards for a ll pressure vessels, including documenting that each pressure vessel has been ev aluated and is protected by pressure-relieving device(s) in accordance with reco gnized and generally accepted good engineering practices, such as the ASME Boile r and Pressure Vessel Code. The abatement plan shall establish dates during the next three months when the evaluations and installations of overpressure protect ion shall be completed. Once the plan has been fully implemented, the employer must submit certification of its full compliance with the standard.