Violation Detail
Standard Cited: 19100307 C03 Hazardous (classified) locations.
Inspection Nr: 311611081
Citation: 01020
Citation Type: Serious
Abatement Date: 04/19/2010 X
Initial Penalty: $5,000.00
Current Penalty: $5,000.00
Issuance Date: 03/08/2010
Nr Instances: 3
Nr Exposed: 75
Related Event Code (REC):
Gravity: 10
Report ID: 0524700
Contest Date: 03/31/2010
Final Order: 09/27/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/27/2018 | $5,000.00 | Serious | ||
Penalty | Z: Issued | 03/08/2010 | $5,000.00 | Serious |
Text For Citation: 01 Item/Group: 020 Hazard: REFINERY
29 CFR 1910.307(c)(3): Equipment that is safe for the location was not of a type and design that the employer demonstrates would provide protection from hazards arising from the combustibility and flammability of vapors, liquids, gases, dusts, or fibers invo lved: BP-Husky Refining, LCC - Oregon, Ohio: On or about September 10, 2009, the employer failed to ensure that electrical lighting equipment met the temperatur e rating (T-rating) requirements in accordance with the electrical classificatio n diagram for the refinery, in that: a.At the FCC Switchrack 3C, four (4) Thomas & Betts - Hazlux 100w Incandescent light units had a T-rating of T2A, when the electrical classification diagram for the unit indicated that a T3 rating was re quired; b.At the Alky 2 Reactor (PR-511382), three (3) Crouse Hinds 100w Mercury , 175 MH, and one (1) Crouse Hinds 100w Incandescent VMVM light units had a T- r ating of T2A, B or D, when the electrical classification diagram for the unit in dicated that a T3 rating was required; c.At the Alky 1 Compressor Switchrack, one (1) Crouse Hinds 175 w MH VMVM light unit had a T-rating of T2A or B, when the electrical classification diagram for the unit indicated that a T3 rating was required. In accordance with 29 CFR 1903 .19(d), abatement certification is required for this violation (using the CERTIF ICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstr ating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or re pair of the equipment, photographic or video evidence of abatement, or other wri tten records.t,