Violation Detail
Standard Cited: 19101025 H01 Lead.
Inspection Nr: 283699.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 12/31/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/30/2012
Nr Instances: 32
Nr Exposed: 500
Related Event Code (REC):
Gravity: 10
Report ID: 0936200
Contest Date:
Final Order: 09/27/2012
Emphasis:
Substance: BWPB
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $0.00 | 12/31/2013 | Serious | ||
Penalty | Z: Issued | 08/30/2012 | $0.00 | 09/26/2012 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.1025(h)(1): All surfaces shall be maintained as free as practicable of accumulations of lead: a) At Bldg. 94, Quickie shop, top of Dustron grind booth 039809 - On or about 2/16/12, lead dusts were allowed to accumulate. b) At Bldg. 94, Quickie shop, top of panel of Dustron 039809 grind booth - On or about 2/16/12, lead dusts were allowed to accumulate. c) At Bldg. 94, Wing Shop, Dustron grind booth floor - On or about 2/16/12, lead dusts were allowed to accumulate. d) At Bldg. 94, Wing shop, top of black metal cabinet - On or about 2/16/12, lead dusts were allowed to accumulate. e) At Bldg. 94, Bldg. 94, Wing shop, cart - On or about 2/16/12, lead dusts were allowed to accumulate. f) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, lead dusts were allowed to accumulate. g) At Bldg. 94, South lunch room, underneath microwave, by window - On or about 2/16/12, lead dusts were allowed to accumulate. h) At Bldg. 94, E-37 area adjacent to emergency shower, top of cabinet - On or about 2/16/12, lead dusts were allowed to accumulate. i) At Bldg. 94, South mens locker room - On or about 2/16/12, lead dusts were allowed to accumulate. j) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, lead dusts were allowed to accumulate. k) At Bldg. 94, North lunchroom, south side Gatorade dispenser - On or about 2/16/12, lead dusts were allowed to accumulate. l) At Bldg. 94, North womens locker room - On or about 2/16/12, lead dusts were allowed to accumulate. m) Bldg. 94, Hangar, Near column F-19, Top of electrical panel adjacent to 5-3-LP-1-02 - On or about 4/10/12, lead dusts were allowed to accumulate. n) At Bldg. 94, Administration side, F/A-18 conference room, Return air vent - On or about 4/10/12, lead dusts were allowed to accumulate. o) At Bldg. 94, Administration side, Supervisor's office, return air vent above kitchenette - On or about 4/10/12, lead dusts were allowed to accumulate. p) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, lead dusts were allowed to accumulate. q) At Bldg. 94, Mezzanine, Eyewash - On or about 4/10/12, lead dusts were allowed to accumulate. r) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, lead dusts were allowed to accumulate. s) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, lead dusts were allowed to accumulate. t) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, lead dusts were allowed to accumulate. u) At Bldg. 94, Mezzanine, Top of red tool box - On or about 4/10/12, lead dusts were allowed to accumulate. v) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, lead dusts were allowed to accumulate. w) At Bldg. 94, Mezzanine, Fencing above the Bonding shop - On or about 4/10/12, lead dusts were allowed to accumulate. x) At Bldg. 94, First floor, Adjacent to stairs, Left of electrical panel L4.5 - On or about 4/10/12, lead dusts were allowed to accumulate. y) At Bldg. 94, First floor, Engineering and Supervisor's office, top of cabinet - On or about 4/10/12, lead dusts were allowed to accumulate. z) At Bldg. 94, First floor, Engineering and Supervisor's office, Fax machine - On or about 4/10/12, lead dusts were allowed to accumulate. aa) At Bldg. 94, Mezzanine, Hallway ledge adjacent to fire extinguisher - On or about 4/10/12, lead dusts were allowed to accumulate. ab) At Bldg. 94, Mezzanine, Hallway, Top of door frame - On or about 4/10/12, lead dusts were allowed to accumulate. ac) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, lead dusts were allowed to accumulate. ad) At Bldg. 94, E-37 floor below emergency shower - On or about 4/10/12, lead dusts were allowed to accumulate. ae) At Bldg. 94, Middle quad desk, MSDS binder - On or about 4/10/12, lead dusts were allowed to accumulate. af) At Bldg. 94, Middle quad desk, Employee clock out computer keyboard - On or about 4/10/12, lead dusts were allowed to accumulate. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with lead.