Violation Detail
Standard Cited: 19101025 E03 IV Lead.
Inspection Nr: 1523378.015
Citation: 01013C
Citation Type: Other
Abatement Date: 11/18/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/30/2021
Nr Instances: 6
Nr Exposed: 150
Related Event Code (REC): R
Gravity: 10
Report ID: 0420600
Contest Date: 10/26/2021
Final Order: 01/05/2023
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/05/2023 | $0.00 | 11/18/2021 | Other | |
Penalty | C: Contested | 11/05/2021 | $0.00 | 11/18/2021 | Serious | |
Penalty | Z: Issued | 09/30/2021 | $0.00 | 11/18/2021 | Serious |
Text For Citation: 01 Item/Group: 013C Hazard:
29 CFR 1910.1025(e)(3)(iv): Written compliance programs for lead were not revised and updated annually to reflect the current status of the program: a) Furnace Department: On or about 4/5/2021, the written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging from 250 �g/m^3 - 8,570 �g/m^3 in excess of the reduced permissible exposure limit (PEL) of 33 �g/m^3 for employees. b) RMPC Department: On or about 4/5/2021, written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging from 80 �g/m^3 - 2,500 �g/m^3 in excess of the reduced PEL of 33 �g/m^3. c) Refining Department: On or about 4/5/2021, written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging from 360 �g/m^3 - 3,160 �g/m^3 in excess of the reduced PEL of 33 �g/m^3. d) Maintenance Department: On or about 4/5/2021, written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging from 70 �g/m^3 - 1, 110 �g/m^3 in excess of the reduced PEL of 33 �g/m^3. e) Hygiene Department: On or about 4/5/2021, written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging at approximately 60 �g/m^3 in excess of the reduced PEL of 33 �g/m^3. f) Environmental Controls Department: On or about 4/5/2021, written compliance plan has not been updated since 10/16/2017 for employees exposed to inorganic lead ranging from 250 �g/m^3 - 510 �g/m^3 in excess of the reduced PEL of 33 �g/m^3.