Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1482431.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/05/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0418800
Contest Date:
Final Order: 12/03/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/03/2020 | $0.00 | Serious | ||
Penalty | Z: Issued | 11/05/2020 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): On or about 7/8/2020, at the Roll Form Department, List Industries Inc., 401 Jim Moran Blvd, Deerfield Beach, FL 33442. Superior Hollow-T line, employees were exposed to a caught by hazard while working and/or walking by a belt and pulley assembly located 18" approximately above floor and under a roll forming machine (i.e. Dahlstrom, Model 400-12, Serial 503) which was not guarded.