Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1460284.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,603.00
Current Penalty: $5,300.00
Issuance Date: 07/21/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 07/29/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/29/2020 | $5,300.00 | Serious | ||
Penalty | Z: Issued | 07/21/2020 | $10,603.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about January 29, 2020, the guard of the chipper feeder did not fully enclose the belt. This condition exposed employees to amputation hazards.