Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1457252.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,446.00
Current Penalty: $9,446.00
Issuance Date: 06/03/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0419700
Contest Date:
Final Order: 06/30/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/03/2020 | $9,446.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about January 21, 202020, at the Lake Crossing Apartments in Gainesville, at the northwest end of Building K, on the 6:12 pitch second-story roof, the portable aluminum extension ladder used to access the third-story roof from the second-story roof did not extend at least feet above the upper landing surface, exposing 3 employees to a 10 foot fall hazard.