Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1430148.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 03/18/2020 2
Initial Penalty: $2,892.00
Current Penalty: $1,735.20
Issuance Date: 01/30/2020
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 02/13/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/13/2020 | $1,735.20 | 03/18/2020 | Serious | |
Penalty | Z: Issued | 01/30/2020 | $2,892.00 | 03/18/2020 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) At the facility, batch tire pyrolysis unit area: On or about August 30, 2019 during initial start up and monitoring of a rotary pyrolysis reactor the belt drive pulleys were not guarded, presenting a caught-in hazard to employees.