Violation Detail
Standard Cited: 19101027 D01 I Cadmium
Inspection Nr: 1424902.015
Citation: 01007C
Citation Type: Serious
Abatement Date: 02/10/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/28/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0625700
Contest Date: 02/12/2020
Final Order: 06/22/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/22/2020 | $0.00 | 02/10/2020 | Serious | |
Penalty | C: Contested | 02/25/2020 | $0.00 | 02/10/2020 | Serious | |
Penalty | Z: Issued | 01/28/2020 | $0.00 | 02/10/2020 | Serious |
Text For Citation: 01 Item/Group: 007C Hazard:
29 CFR 1910.1027(d)(1)(i): The employer did not determine whether any employee was exposed to cadmium at or above the action level. a) Back Drop Storage Area: The employer did not ensure that surfaces were maintained free from Cadmium accumulation. A wipe sample from the canvas backdrop storage area was collected on August 21, 2019 revealing 0.5280 micrograms of Cadmium was present.